Line interative UPS
DG Series
600-3000VA | 140V-300V
DG series line-interactive UPS is specially designed for Personal Computer with multi-functions. The lightweight, compact design perfectly fits the limited space. The UPS is equipped with two boosts and one buck AVR to stabilize the wide input voltage range.

Specification
INVAGU DG Series: Line Interactive UPS for Computers and Offices
INVAGU DG Series UPS systems provide battery backup for compatible computers and office equipment during power interruptions. Automatic Voltage Regulation (AVR) helps manage supply fluctuations, while a simulated sine wave output supports compatible loads when the UPS runs on battery power.
The attached INVAGU manuals cover 800, 1500, 2000 and 3000 VA units. The INI2K29BTSP2 manual specifies a 2000 VA UPS with a nominal 230 V input and a 140–300 V input range. Select the exact model to match the connected equipment and its operating requirements.
Choosing the Right UPS Capacity
Check both the VA rating and the actual watt limit on the unit nameplate. Battery runtime depends on the connected load, battery capacity and battery condition. A higher VA rating alone does not guarantee a specific backup time. For equipment requiring a pure sine wave, explore the INVAGU MEMOPOWER-III online UPS.
For UPS sales and project quotations in Saudi Arabia, contact INVAGU to select the right power rating and battery configuration. WhatsApp +966595103434 or contact us.
Download INVAGU User Manuals
Select the manual matching your UPS model and document reference.
INVAGU DG Series Features
- Automatic Voltage Regulation: Boost and buck functions manage supply fluctuations within the operating limits of the selected model.
- DC start: Start the UPS without an AC supply when sufficient battery charge is available.
- Automatic restart: Resume operation after the AC supply recovers, subject to the operating state of the UPS.
- Load and battery protection: Overload, overcharge and overdischarge protection as specified in the relevant manual.
- Status indicators and audible alarms: Monitor AC operation, battery operation and fault conditions, with warnings for low battery and overload.
- LCD monitoring on the attached 3000 VA version: View input voltage, output voltage, battery level and load level.
- Office applications: A desktop design for personal computers and other equipment compatible with a simulated sine wave output.
INVAGU DG Series Technical Specifications
| Manuals cover | 800 / 1500 / 2000 / 3000 VA |
|---|---|
| Nominal voltage | 230 VAC |
| Input range: 800 / 1500 / 2000 VA | 140–300 VAC; consult the 3000 VA manual for that version’s input limits |
| Battery-mode output waveform | Simulated sine wave |
| Battery-mode voltage regulation | ±10% |
| Frequency | 50 or 60 Hz; battery-mode frequency regulation: ±1 Hz |
| Typical transfer time | 4–8 ms |
| 800 / 1500 VA battery system | 12 / 24 VDC respectively |
| INI2K29BTSP2 2000 VA batteries | 2 × 12 V / 9 Ah |
| 3000 VA batteries | 4 × 12 V / 9 Ah; 48 VDC battery system |
| Typical recharge period stated | 6–8 hours to approximately 90%, depending on the model and operating conditions |
| Operating temperature | 0–40 °C; non-condensing conditions |
These values apply to the attached model manuals. Dimensions, interfaces and indicators vary by model. Confirm the nameplate watt rating and load compatibility before selecting a unit.
INVAGU DG Series Line Interactive UPS in Saudi Arabia
Battery backup for computers and office equipment, with automatic voltage regulation and simulated sine wave output on battery.
DG Series Line Interactive UPS: Key Selection Facts
Category: Line Interactive UPS. Range: 600–3000 VA series. Application: computers and compatible office equipment.
- AVR boost and buck regulation
- Automatic restart after AC recovery
- Model-specific INVAGU manuals for 800, 1500, 2000 and 3000 VA
Selection for Saudi Arabia and Regional Projects
For projects in Riyadh, Jeddah, Dammam and other Saudi cities, specify the installation city, input and output voltage, frequency, phase arrangement and load. For enquiries from other Arab markets, include the destination country and local electrical requirements.
How do I choose the UPS capacity and battery runtime?
List the connected load in watts and VA, the starting or inrush demand, phase configuration and required backup time. Runtime depends on the load, battery capacity and condition; a kVA rating alone does not specify backup minutes.
What determines the price of DG Series Line Interactive UPS?
The exact UPS version, output watt rating, battery quantity and capacity, monitoring options and installation requirements determine the quotation. Send the load, required runtime and destination for model-specific pricing and availability.
Compare Related INVAGU Solutions
Request a Quote or Product Advice
Contact INVAGU through our sales enquiry form or WhatsApp +966595103434. Our contact office is in Dammam, Saudi Arabia. Share the exact model and project requirements so that pricing, compatibility and availability can be confirmed.